Oil-free serial-compressor stations
with membrane dryers
The standard station has an oil-free compressor, control gear, and quick coupling with hose nozzle. The compact design allows the cooler and the membrane dryer to be mounted on the top of the pressure receiver, which features the antibacterial internal coating. Further options such as a sterile filter and an operational hours meter are available.
Compressed air in medical quality
The robust membrane dryer technology and innovative filter system (< 67 ppm), combined with the oil-free compressor design, help to pro- duce hygienically clean and dry compressed air.
The system has a dew point of -27 °C (-17 F) at 7 bars (100 psi) pressure. The compressor station is available with two B-160 compressor heads mounted on a 90 l air receiver.
Technical date of the membrane dryers:
- Pressure range (usable) 4 – 10 bar (60-145 psi)
- Operating pressure 7 bar (100 psi)
- Ambient temperature 5 – 40 °C (41 – 104 F)
- Dew point reduction 35 Kelvin (-396 F)
- Microfilter (built-in) 3 micron
| Type | Free air flow at 0 bar |
Air Flow at 5 bar |
Receiver capacity |
Rating data |
Dimensions |
Weight | |
| Voltage | Freq. | ||||||
| (l/min) | (l/min) | (l) | (V) | (Hz) | L x W x H (mm) | (kg) |
|
| TA-065M | 65 | 35 | 25 | 230 | 50/60 | 620 x 440x 670 | 38 |
| TA-100 M | 110 | 60 | 25 | 230 | 50/60 | 620 x 440x 670 | 43 |
| TAG-132 M | 130 | 64 | 25 | 230 | 50/60 | 620 x 440x 670 | 40 |
| HA-160 M | 160 | 95 | 55 | 230 | 50/60 | 920 x 450x 720 | 57 |
| HB-200 M | 200 | 120 | 55 | 400 | 50/60 | 920 x 450x 720 | 66 |
| HB-304 M | 295 | 189 | 55 | 400 | 50/60 | 920 x 450x 720 | 79 |